{"id":7044,"date":"2026-10-30T00:00:47","date_gmt":"2026-10-29T16:00:47","guid":{"rendered":"https:\/\/www.hitekenergy.com\/?p=7044"},"modified":"2026-11-02T15:42:56","modified_gmt":"2026-11-02T07:42:56","slug":"grid-forming-vs-grid-following-inverters-for-battery-energy-storage","status":"publish","type":"post","link":"https:\/\/www.hitekenergy.com\/pt\/news\/grid-forming-vs-grid-following-inverters-for-battery-energy-storage\/","title":{"rendered":"Inversores formadores de rede versus inversores seguidores de rede para armazenamento de energia em baterias  \u00a0"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-7038\" src=\"https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/Grid-Forming-vs-Grid-Following-Inverters-for-Battery-Energy-Storage.png\" alt=\"Inversores formadores de rede versus inversores seguidores de rede para armazenamento de energia em baterias\" width=\"477\" height=\"566\" srcset=\"https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/Grid-Forming-vs-Grid-Following-Inverters-for-Battery-Energy-Storage.png 477w, https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/Grid-Forming-vs-Grid-Following-Inverters-for-Battery-Energy-Storage-253x300.png 253w, https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/Grid-Forming-vs-Grid-Following-Inverters-for-Battery-Energy-Storage-10x12.png 10w\" sizes=\"(max-width: 477px) 100vw, 477px\" \/><\/p>\n<p>Seguir a rede e formar a rede s\u00e3o os dois m\u00e9todos pelos quais o inversor de bateria pode interagir com a rede CA. O inversor que segue a rede acompanha a forma de onda da tens\u00e3o existente para gerenciar a corrente, enquanto o inversor que forma a rede gera sua pr\u00f3pria forma de onda de tens\u00e3o. Isso permite que ele auxilie a rede mesmo quando n\u00e3o h\u00e1 sinal externo dispon\u00edvel. Ter um ou outro r\u00f3tulo n\u00e3o garante a capacidade de partida a frio, o direito de opera\u00e7\u00e3o em ilha ou qualquer abordagem espec\u00edfica para o gerenciamento de falhas. Os engenheiros devem escolher o modo de controle correto.<\/p>\n<h2><strong><b>A diferen\u00e7a de controle em uma compara\u00e7\u00e3o.<\/b><\/strong><\/h2>\n<p>A diferen\u00e7a \u00e9 mais f\u00e1cil de perceber no ponto de conex\u00e3o. Os dispositivos de acompanhamento da rede monitoram a fase atual da rede e, em seguida, injetam corrente no sistema. Os dispositivos formadores de rede definem suas pr\u00f3prias metas de tens\u00e3o e frequ\u00eancia dentro de limites preestabelecidos. Eles tamb\u00e9m equilibram a pot\u00eancia com outras unidades com base em configura\u00e7\u00f5es internas. Independentemente do tipo, todo projeto ainda requer prote\u00e7\u00e3o de seguran\u00e7a, limites de energia, gerenciamento t\u00e9rmico e l\u00f3gica comprovada para a comuta\u00e7\u00e3o dos modos.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"184\"><strong><b>Pergunta de design<\/b><\/strong><\/td>\n<td width=\"184\"><strong><b>Seguidor de grade<\/b><\/strong><\/td>\n<td width=\"184\"><strong><b>Forma\u00e7\u00e3o de grade<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Refer\u00eancia<\/td>\n<td width=\"184\">Segue a tens\u00e3o CA externa<\/td>\n<td width=\"184\">Define a refer\u00eancia de tens\u00e3o CA local.<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Alvo de controle t\u00edpico<\/td>\n<td width=\"184\">Corrente ou pot\u00eancia ativa e reativa<\/td>\n<td width=\"184\">Compartilhamento de tens\u00e3o, frequ\u00eancia e pot\u00eancia<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Comportamento de grade fraca<\/td>\n<td width=\"184\">Baseia-se em alta qualidade de refer\u00eancia.<\/td>\n<td width=\"184\">Posso fornecer uma refer\u00eancia se a constru\u00e7\u00e3o estiver correta.<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Opera\u00e7\u00e3o na ilha<\/td>\n<td width=\"184\">Necessita de uma fonte de forma\u00e7\u00e3o separada.<\/td>\n<td width=\"184\">Funciona com os controles e a seguran\u00e7a adequados.<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Verifica\u00e7\u00e3o<\/td>\n<td width=\"184\">Sincroniza\u00e7\u00e3o e verifica\u00e7\u00e3o do fluxo atual<\/td>\n<td width=\"184\">Testes de estabilidade e compartilhamento<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>Onde o seguimento de grade funciona bem<\/b><\/strong><\/h2>\n<p>Uma rede el\u00e9trica robusta oferece sinais est\u00e1veis \u200b\u200bde tens\u00e3o e frequ\u00eancia. Nesses casos, um sistema de armazenamento de energia em baterias (BESS) com capacidade de seguir a rede pode enviar energia ativa e gerenciar energia reativa com facilidade. Ele atende \u00e0 maioria das normas de conex\u00e3o padr\u00e3o sem problemas. No entanto, seu desempenho \u00e9 confi\u00e1vel apenas dentro de certos limites de resist\u00eancia da rede e de seguran\u00e7a. N\u00e3o se deve chamar um projeto com capacidade de seguir a rede de \"formador de rede\" apenas porque ele reage rapidamente a mudan\u00e7as de frequ\u00eancia ou auxilia no gerenciamento de energia reativa.<\/p>\n<h2><strong><b>Por que as grades fracas alteram o projeto<\/b><\/strong><\/h2>\n<p><em><i> <img decoding=\"async\" class=\"aligncenter size-full wp-image-7039\" src=\"https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/HITEKESS-inverter.png\" alt=\"Inversor HITEKESS\" width=\"557\" height=\"554\" srcset=\"https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/HITEKESS-inverter.png 557w, https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/HITEKESS-inverter-300x298.png 300w, https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/HITEKESS-inverter-150x150.png 150w, https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/HITEKESS-inverter-12x12.png 12w, https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/HITEKESS-inverter-100x100.png 100w\" sizes=\"(max-width: 557px) 100vw, 557px\" \/><\/i><\/em><\/p>\n<p>Em uma rede el\u00e9trica com baixa estabilidade, a tens\u00e3o oscilar\u00e1 bastante se houver fluxo de corrente proveniente do inversor. Caso v\u00e1rios sistemas de sincroniza\u00e7\u00e3o com a rede operem em conjunto, podem causar interfer\u00eancia entre si devido aos seus circuitos de travamento de fase (PLL). Os dispositivos formadores de rede ajudam a estabilizar a tens\u00e3o e a frequ\u00eancia. No entanto, esses dispositivos devem ser configurados de acordo com a rede, os geradores e a carga. Qualquer estudo deve analisar as piores condi\u00e7\u00f5es da rede.<\/p>\n<ul>\n<li>Mapeie os n\u00edveis m\u00ednimos de curto-circuito e a faixa de imped\u00e2ncia da rede.<\/li>\n<li>Procure por oscila\u00e7\u00f5es de tens\u00e3o e frequ\u00eancia ap\u00f3s grandes mudan\u00e7as na carga ou na pot\u00eancia.<\/li>\n<li>Verifique como a unidade funciona com outros inversores e rel\u00e9s de seguran\u00e7a.<\/li>\n<li>Defina o que acontece quando o sistema de armazenamento de energia em baterias (BESS) atinge seu limite de corrente ou de estado de carga (SOC).<\/li>\n<li>Confirme quem \u00e9 o respons\u00e1vel por atualizar os modelos e controlar as configura\u00e7\u00f5es.<\/li>\n<\/ul>\n<h2><strong><b>A forma\u00e7\u00e3o de uma grade n\u00e3o significa automaticamente um come\u00e7o preto.<\/b><\/strong><\/h2>\n<p>Grid formation starts from scratch and involves a lot of procedures. First, you will require back-up power, available DC power, and ability to start the PCS. Then, there is magnetization of transformers, load pickup, and other procedures. <strong><a href=\"https:\/\/www.hitekenergy.com\/pt\/inverter\/atess-battery-inverter-pcs1500hv\/\">Grid-forming PCS<\/a><\/strong> will give an AC signal for formation, however, the site should be able to handle that initial surge of power. The procedure is not supposed to exceed the limits of battery or current. It is important to test it on practice.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"184\"><strong><b>Escen\u00e1rio<\/b><\/strong><\/td>\n<td width=\"184\"><strong><b>Pergunta para a especifica\u00e7\u00e3o<\/b><\/strong><\/td>\n<td width=\"184\"><strong><b>Evid\u00eancias de aceita\u00e7\u00e3o<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Energiza\u00e7\u00e3o de barramento morto<\/td>\n<td width=\"184\">O PCS consegue alimentar o barramento e o transformador?<\/td>\n<td width=\"184\">Registros de dados de tens\u00e3o e corrente de pico<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Carregar coleta<\/td>\n<td width=\"184\">Qual a quantidade m\u00e1xima de carga que pode ser adicionada de uma s\u00f3 vez?<\/td>\n<td width=\"184\">Dados de recupera\u00e7\u00e3o de frequ\u00eancia e tens\u00e3o<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Opera\u00e7\u00e3o paralela<\/td>\n<td width=\"184\">Como a carga \u00e9 dividida?<\/td>\n<td width=\"184\">Tend\u00eancias de P e Q com outras unidades<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Retorno da grade<\/td>\n<td width=\"184\">Como ele se reconecta \u00e0 rede?<\/td>\n<td width=\"184\">Seletor de modo e registros de seguran\u00e7a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>Limites de corrente e prote\u00e7\u00e3o ainda importam<\/b><\/strong><\/h2>\n<p>A corrente do inversor possui limites r\u00edgidos devido ao calor e \u00e0s especifica\u00e7\u00f5es do chip. Em caso de curto-circuito, uma unidade formadora de rede pode n\u00e3o fornecer a mesma corrente de falha de longo prazo que um gerador convencional. Os planos de seguran\u00e7a devem utilizar os modelos de falha espec\u00edficos fornecidos pelo fabricante. \u00c9 importante verificar o transformador, as chaves e as configura\u00e7\u00f5es dos rel\u00e9s como um sistema \u00fanico. Isso \u00e9 crucial para locais isolados com m\u00faltiplas fontes de energia.<\/p>\n<h2><strong><b>Limita\u00e7\u00f5es na energia das baterias afetam os servi\u00e7os de rede.<\/b><\/strong><\/h2>\n<p>Gerar tens\u00e3o \u00e9 uma tarefa de software, mas manter o fluxo de energia requer energia armazenada real e espa\u00e7o no PCS (Sistema de Controle de Pot\u00eancia). Se um operador usar toda a bateria para negocia\u00e7\u00e3o, mas prometer suporte de frequ\u00eancia, pode n\u00e3o haver reserva de SOC (Estado de Carga) suficiente para uma emerg\u00eancia. \u00c9 preciso definir uma pol\u00edtica clara para reservas. Defina quanto tempo elas duram e como se recuperam. O BMS (Sistema de Gerenciamento de Bateria) deve informar o PCS e o EMS (Sistema de Gerenciamento de Emerg\u00eancia) sobre os limites de corrente para que n\u00e3o solicitem energia que n\u00e3o esteja dispon\u00edvel.<\/p>\n<p>A maneira como o <a href=\"https:\/\/www.hitekenergy.com\/pt\/news\/bms-vs-ems-vs-pcs-in-a-battery-energy-storage-system\/\"><strong><u><b>BMS, EMS e PCS<\/b><\/u><\/strong><\/a>\u00a0A colabora\u00e7\u00e3o \u00e9 fundamental na defini\u00e7\u00e3o dessas regras.<\/p>\n<h2><strong><b>Selecione por cen\u00e1rio operacional, n\u00e3o por r\u00f3tulo.<\/b><\/strong><\/h2>\n<p>A standard factory site might only need basic power flow and reactive help without ever leaving the grid. A remote microgrid, however, needs the <strong><a href=\"https:\/\/www.hitekenergy.com\/pt\/solution\/contaianerized-bess\/\">MELHOR<\/a><\/strong> to start the AC bus and lead a diesel generator. Some utility sites need grid-forming traits only when the main grid is weak. For every project, clearly state who provides the voltage signal, how the system switches modes, and who can change the settings.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"184\"><strong><b>Estudo de caso do projeto<\/b><\/strong><\/td>\n<td width=\"184\"><strong><b>Ponto de partida prov\u00e1vel<\/b><\/strong><\/td>\n<td width=\"184\"><strong><b>Estudo cr\u00edtico<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"184\">C&amp;I de rede forte<\/td>\n<td width=\"184\">Seguir uma grade geralmente \u00e9 suficiente.<\/td>\n<td width=\"184\">Qualidade da conex\u00e3o e da energia<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Microrrede isolada<\/td>\n<td width=\"184\">Necessita de uma fonte formadora<\/td>\n<td width=\"184\">Carregar etapas e iniciar em preto<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Sistemas de armazenamento de energia em baterias (BESS) para concession\u00e1rias de baixa tens\u00e3o na rede el\u00e9trica<\/td>\n<td width=\"184\">Analise ambos os modos de controle.<\/td>\n<td width=\"184\">Rel\u00e9s de estabilidade e seguran\u00e7a<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">Transi\u00e7\u00e3o de backup<\/td>\n<td width=\"184\">A l\u00f3gica de comuta\u00e7\u00e3o \u00e9 vital.<\/td>\n<td width=\"184\">Isolamento e resincroniza\u00e7\u00e3o<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>O que perguntar durante o processo de aquisi\u00e7\u00e3o e testes<\/b><\/strong><\/h2>\n<p><em><i> <img decoding=\"async\" class=\"aligncenter size-full wp-image-7041\" src=\"https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/inverter.png\" alt=\"inversor\" width=\"549\" height=\"477\" srcset=\"https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/inverter.png 549w, https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/inverter-300x261.png 300w, https:\/\/www.hitekenergy.com\/wp-content\/uploads\/2026\/10\/inverter-14x12.png 14w\" sizes=\"(max-width: 549px) 100vw, 549px\" \/><\/i><\/em><\/p>\n<p>Solicite uma lista clara de todos os modos suportados e quando eles s\u00e3o ativados. O fornecedor deve fornecer modelos testados, dados de corrente de falha e limites de corrente. Ele tamb\u00e9m deve demonstrar como o sistema alterna entre os modos e fornecer planos de teste no local. Afirmar ser um sistema \"formador de rede\" n\u00e3o \u00e9 suficiente. Voc\u00ea precisa de um estudo que comprove a estabilidade do sistema com a sua fia\u00e7\u00e3o espec\u00edfica e outras unidades de energia.<\/p>\n<ul>\n<li>Defina as faixas exatas de tens\u00e3o, frequ\u00eancia e n\u00edveis de queda de tens\u00e3o (droop).<\/li>\n<li>Liste os limites de pot\u00eancia ativa e reativa em todos os pontos principais.<\/li>\n<li>Descreva como a unidade limita a corrente e reage a falhas.<\/li>\n<li>Teste como ele transita entre estar conectado \u00e0 rede e estar isolado.<\/li>\n<li>Mantenha um registro do software e das configura\u00e7\u00f5es utilizadas para a aprova\u00e7\u00e3o final.<\/li>\n<\/ul>\n<h2><strong><b>Sobre HITEK ENERGY<\/b><\/strong><\/h2>\n<p>A HITEK ENERGY CO., LTD \u00e9 uma fabricante de produtos de armazenamento de energia para empresas e ind\u00fastrias. Seus sistemas oferecem uma base para combinar baterias e controladores PCS com as necessidades espec\u00edficas de cada local. Se voc\u00ea precisa de recursos de forma\u00e7\u00e3o de rede, deve verificar a compatibilidade com a configura\u00e7\u00e3o PCS escolhida e os estudos do projeto. Conhecer apenas a marca n\u00e3o garante que a fun\u00e7\u00e3o espec\u00edfica funcionar\u00e1 em seu local.<\/p>\n<p>Os compradores podem consultar o HITEKESS\u00a0<a href=\"https:\/\/www.hitekenergy.com\/pt\/inverter\/\"><strong><u><b>portf\u00f3lio de sistemas de armazenamento de energia<\/b><\/u><\/strong><\/a>\u00a0para iniciar sua an\u00e1lise t\u00e9cnica.<\/p>\n<h2><strong><b>Conclus\u00e3o<\/b><\/strong><\/h2>\n<p>O controle de seguimento de rede utiliza o sinal CA atual para manter a sincroniza\u00e7\u00e3o. O controle de forma\u00e7\u00e3o de rede cria seu pr\u00f3prio sinal para suportar sistemas fracos ou isolados. Escolha o modo com base em como o local ir\u00e1 operar na pr\u00e1tica. Em seguida, verifique a estabilidade, os limites de corrente e as reservas de bateria utilizando modelos reais e realizando testes no local.<\/p>\n<h2><strong><b>FAQ<\/b><\/strong><\/h2>\n<h3><strong><b>Um sistema de armazenamento de energia em baterias (BESS) que segue a rede el\u00e9trica pode operar em uma ilha?<\/b><\/strong><\/h3>\n<p>Somente se houver outra fonte para definir a tens\u00e3o e a frequ\u00eancia. Todo o projeto da ilha deve ser minuciosamente elaborado por um engenheiro.<\/p>\n<h3><strong><b>Todo inversor formador de rede oferece partida a frio?<\/b><\/strong><\/h3>\n<p>N\u00e3o. Para dar partida a frio, \u00e9 necess\u00e1rio ter as baterias e os transformadores certos, al\u00e9m de um planejamento cuidadoso para a adi\u00e7\u00e3o de cargas.<\/p>\n<h3><strong><b>A forma\u00e7\u00e3o de rede \u00e9 sempre melhor para um sistema de armazenamento de energia em baterias?<\/b><\/strong><\/h3>\n<p>N\u00e3o. Depende da malha urbana. Uma malha urbana bem estruturada geralmente n\u00e3o precisa desses recursos adicionais.<\/p>\n<h3><strong><b>O que os compradores devem verificar em uma declara\u00e7\u00e3o de forma\u00e7\u00e3o de rede?<\/b><\/strong><\/h3>\n<p>Verifique os modos, modelos, capacidades de corrente e como ele lida com a comuta\u00e7\u00e3o e a seguran\u00e7a.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong><b>SISTEMAS DE ARMAZENAMENTO DE ENERGIA EM BATERIAS HITEKESS<\/b><\/strong><\/h2>\n<h3><b>1.\u00a0<\/b><strong><b>Sistema de Energia Solar Completo Hitek de 250 kW com Inversor, Compat\u00edvel com Sistemas On-Grid, H\u00edbridos e Off-Grid de 50 kW, 100 kW, 150 kW e 250 kW - Custo Total - Sistema Integrado de Pain\u00e9is Solares<\/b><\/strong><\/h3>\n<p><strong><b>Modelo: HT250KW-HY<\/b><\/strong><\/p>\n<h3><b>2.\u00a0<\/b><strong><b>Sistemas solares h\u00edbridos off-grid de 100 kW, 200 kW, 250 kW, 500 kW e 1 MW para uso comercial. Sistema solar completo de 1 megawatt com baterias de l\u00edtio de reserva de 500 kWh, 1 MWh e 2 MWh.<\/b><\/strong><\/h3>\n<p><strong><b>Modelo:<\/b><\/strong><strong><b>HT500KW-HY<\/b><\/strong><\/p>\n<h3><b>3.\u00a0<\/b><strong><b>Suporte \u00e0 rede el\u00e9trica com projeto profissional: 500 kWh, 800 kWh, 1 MWh, 2 MWh. Sistema completo de armazenamento de energia em cont\u00eaineres com baterias: 500 kWh, 1 MWh.<\/b><\/strong><\/h3>\n<p><strong><b>Modelo: HT500KW-HY<\/b><\/strong><\/p>\n<h3><b>4.\u00a0<\/b><strong><b>Sistema de energia solar Hitek 100 kW 200 kW 250 kW 500 kW on-off Grid All in One, com armazenamento de energia em cont\u00eainer de 20 p\u00e9s com baterias LiFePO4 de 500 kW e 1 MWh.<\/b><\/strong><\/h3>\n<p><strong><b>Modelo: HT-500\/1MWH-EC<\/b><\/strong><\/p>\n<h3><b>5.\u00a0<\/b><strong><b>Sistema h\u00edbrido completo Hitek de 100 kW, 200 kW, 250 kW e 500 kW para ambientes internos e externos, sistema solar de 500 kW e sistema de energia solar comercial de 1000 kWh com bateria.<\/b><\/strong><\/h3>\n<p><strong><b>Modelo: HT-500\/1000-EC<\/b><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Grid following and grid forming are the two methods by which the battery inverter can interact with the AC grid. Grid following inverter follows the existing voltage wave form for managing the current while a grid forming inverter generates its own voltage waveform. It enables it to provide help to the grid even when there [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7038,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-7044","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/posts\/7044","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/comments?post=7044"}],"version-history":[{"count":4,"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/posts\/7044\/revisions"}],"predecessor-version":[{"id":7049,"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/posts\/7044\/revisions\/7049"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/media\/7038"}],"wp:attachment":[{"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/media?parent=7044"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/categories?post=7044"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hitekenergy.com\/pt\/wp-json\/wp\/v2\/tags?post=7044"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}